Initialization Problem 2
An unexpected software configuration is loaded.
Solutions:
1.
Log in to the node you think is defined as the load host, and perform the
following steps:
•
Enter the following command:
NCP> SHOW NODE
gateway-node-name CHARACTERISTICS
•
Check the following items in the displayed information:
DECnet node address
Service circuit
Hardware address
Load file specification
•
Does the information displayed match your expectations about the
configuration? If not, correct any errors that you find, and load the
system again. Initialization Problem 1 provides more information
about these items.
2.
Use the following NCP command to check for
"
unknown
"
load hosts:
NCP> TELL
gateway-node-name SHOW EXECUTOR CHARACTERISTICS
One line in this display gives the name of the node that loaded the DEC
MicroServer. If you do not want that node to be a load host, you can
prevent it from loading the DEC MicroServer by deleting the loading
information from its DECnet database. Enter the following command to
delete the information:
NCP> CLEAR NODE
gateway-node-name LOAD FILE
Reload the DEC MicroServer.
Solving DECnet SNA Gateway for Synchronous Transport Problems 1–21