en03d141.fm, 11.03.2008
PL12EN-1300 2008-03
81
Programming
3
3.11.6
Tool / TQ Measurement
c0
03
02
en
.bm
p
Fig. 3-46: Tool / TQ Measurement
testmeas.txtS
This test function recalibrates the system with the values used immediately before the start of a
rundown. The spindle must therefore be released still when this function is called up! Then the
tool is started at zero speed and the torque is continuously measured and displayed. The field
"Current torque" displays the current torque, "Peak torque" displays the highest value measured
since the start of the function. If "Redundancy" is activated, the values of the second transducer
are also displayed.
Note:
Not available on the TMEI.
testmeas.txtE