28
PL12EN-1300 2008-03
en03d141.fm, 11.03.2008
Programming
3
From the Basic Application Builder, the Auto Program feature is available by pressing the <F1>
soft key only when a tool is connected to the controller and if the application is not already pro-
grammed. The <F1> "Auto Program" button should look disabled if there is no tool or if the appli-
cation is programmed or if Angle Control/Torque Monitoring is selected.
The Auto Program feature accepts the Stage 2 target torque and the torque units. Pressing the
cancel button exits the auto program screen without saving changes. Pressing the <OK> button
causes the auto calculations to be done and the results are displayed on the basic screen.
3.2.7
Basic Application Builder / Copy
c0
03
62
en.
b
m
p
Fig. 3-5: Torque Control / Angle Monitor / Copy
From the Basic Application Builder, the user can copy the parameters of an application to one or
more other applications by pressing the Copy <F3> soft key. From this dialog box, the user can
specify the source and target tool and application. When using Copy function from the Basic
Application Builder, all stages of the selected application are copied. Multiple target applications
may be specified by separating the application numbers with a period as shown.