en03d141.fm, 11.03.2008
PL12EN-1300 2008-03
23
Programming
3
The 2-channel model has the following limitations:
• Field Bus (DeviceNet/Profibus): When active, all inputs and outputs are only applicable to the
operation of Tool 1.
• The PFCS communications protocol uses a single Machine ID (MID) for both tools.
• The auto-select feature does not apply to the Oscilloscope screen.
3.1.6
Navigator Menu
Basic Application Builder
Basic Application Builder allows the user to graphically select and program a two-stage rundown
for Torque Control/Angle Monitor (Seq11+Seq30) or Angle Control/Torque Monitor
(Seq11+Seq50) for any of the 255 Applications. The user only enters Torque, Angle, and Speed
Setpoints in one screen. Other parameters such as timers, etc are automatically defaulted to pre-
determined values.
Standard Application Builder
Standard Application Builder allows the user to program up to a 6-stage rundown for any of the
255 Applications. Once the fastening sequences are selected for each stage, the associated
Torque, Angle, Speed, and Advanced parameters can be programmed.
Advanced Application Builder
Advanced Application Builder allows the user to View all Application setups at once, and perform
I/O Mapping. The Application Matrix shows an overview of Application and Stage programming
by displaying the selected Fastening Sequence for each stage. I/O Mapping lets the user select
from a list of functions and assign that function to a given input or output.
RUN Screen
The Run Screen button takes the user directly to the display for Torque, Angle, and Status Indica-
tor Labels. The Oscilloscope function used for diagnosing torque traces is also located in the
Run Screen.
Communications
The Communications Setup allows the user to configure all communications for the Printer and
Serial Data Transmission. Appropriate communications settings for protocol, port, baud rate, etc
can be set in this screen.
Tool Setup
The Tool Setup displays the Tool Memory Data and allows the user to modify this information by
changing it directly or selecting from the Tool Library.
Statistics
Chronological History and associated statistics are viewable from this screen. Data can be
erased and printed as well.
Diagnostics
The System Diagnostics contains screens to determine if the system is functioning properly.
There are diagnostics for I/O, Arcnet, Tool and Tightening Module, Serial Communications, and
Transducer Calibration.