56
PL12EN-1300 2008-03
en03d141.fm, 11.03.2008
Programming
3
2.
Function: Indicates the status of Part ID Data Function:
- “Data function: not configured” (clear LED): Part ID “Data Function” is configured to
"None".
- “Function: None” (yellow LED): Part ID “Configure Data” is enabled, but the Part ID is
invalid or does not match any Configure Data entries.
- “Function: XYZ” (green LED): Part ID “Configure Data” is enabled, and the current Part ID
has engaged function XYZ (see Communications - Part ID help screen for function defini-
tions).
3.
Input status: Indicates whether or not a new Part ID can be entered.
- “Accepting Part ID input” (green LED): A new Part ID may be entered.
- “Not Accepting Part ID input” (red LED): A new Part ID may not be entered.
- A new Part ID may not be entered when the tool trigger is active.
- “NEW INPUT IGNORED!” (red LED): This status is displayed if a new Part ID is entered
while “Not Accepting Part ID input” is true.
Below the Torque and Angle display is the “Status” window. This window displays various mes-
sages related to the tool, rundown status, or errors.
The <F1> “Print” soft key causes any rundown data that has not previously been printed to be
sent to the parallel port printer interface. If the Part ID is configured to “Print Interlock”, the Part ID
is invalidated, and the tool is disabled.
The <F2> “Oscilloscope” soft key displays the Oscilloscope function for evaluating Torque and
Angle curves. It is automatically updated after each cycle.
The Run Screen may be optionally configured to display Rundown Details or Counter information
as shown. These options are available by pressing the Configure <F3> soft key. See "Run
Screen / Configure". Counter information is available for individual applications and tightening
groups (linking). See "Administration / Counter". The rundown details include the application
number, the stage number of the Torque/Angle results currently displayed, the total number of
stages in the application, and the rundown status summary (Good, A High, T Low, etc).
(2-Channel only) Tool display options are Manual Select, Auto Select, and Split Screen. See
"Run Screen / Configure". In the single tool display, when tool 2 is selected, the run screen dis-
play has the labels for the result LEDs on the right side. When navigating to other screens, the
"active" tool for other functions is the tool selected in the "Tool" edit box.
When Split Screen is selected, the side of the display containing the focus (red highlight) deter-
mines the "active" tool. Split Screen limitations:
• With Linking enabled, the total number of tightening positions is not displayed.
• With Linking enabled, the display of the tightening group name is limited to 5 characters. If the
group name is longer than 5 characters, only "Group" is displayed.
• With Part ID enabled, the Part ID status box is not displayed.
• A long Part ID may not be completely displayed.