Tool / Voltages
c0
03
00
en
.bm
p
Fig. 3-45: Tool / Voltages
testvolt.txtS
The table displays the measured voltages of a channel.
These are the most important supply voltages on the measuring board, required for proper
torque and angle measurement. Therefore, these must be monitored continuously. If a voltage is
out of tolerance, it is shown in red.
Designation voltage
Rated value
Tolerance
Logic voltage:
+5 V
+250 mV/-400 mV
Pos. analog Positive analog
voltage
+12 V
±600 mV
Neg. analog Negative analog
voltage
-12 V
±900 mV
testvolt.txtE