O utputs
O0. Cycle OK
O1. Cycle NO K
O2. Torque H igh
O3. Torque Low
O4. Linking O K
O5. Linking NO K
O6. Cycle Com plete
W ith Linking:
O7. Linking Com plete /
Synchronization O ut
W ith Tool Synchronization:
O7. Linking Com plete /
Synchronization O ut
As appropriate
As appropriate
As appropriate
As appropriate
As appropriate
As appropriate
As appropriate
End
Stage1
Start
Stage2
c00287en.bmp
44
PL12EN-1300 2008-03
en03d141.fm, 11.03.2008
Programming
3
Fig. 3-15: Output Timing Diagram
outputs.txtS
Eight relay outputs are available at the Phoenix output connector under the right side door and
are defined as follows:
PIN 1
+24 VDC
PIN 2
Output Common
PIN 3
Output 0
PIN 4
Output 1
PIN 5
Output 2
PIN 6
Output 3
PIN 7
Output 4
PIN 8
Output 5
PIN 9
Output 6
PIN 10
Output 7
PIN 11
Signal Ground
PIN 12
Spare
Each of the physical outputs 0-7 can be programmed to have one of the following definitions:
Not Used
Unused
OK
Active if Torque / Angle / Yield are within programmed limits