en03d141.fm, 11.03.2008
PL12EN-1300 2008-03
29
Programming
3
3.3
Standard Application Builder
3.3.1
Standard Application Builder / View Stages
c0
02
80
en.
bm
p
Fig. 3-6: View Stages
viewstag.txtS
From View Stages, Stages 1-6 and a Backoff Stage are programmable for a given tool and appli-
cation.
When the tool is started, each Stage having a programmed Fastening Sequence will be run in
succession based on the results from the previous stage. The Backoff Stage is used when the
tool is run in the reverse or untighten direction.
When the Counter Clockwise box is checked, each stage is run with the tool tightening in a
counter-clockwise direction. Sequence 41 (angle controlled backout) and the Backoff Stage are
run in the clockwise direction.
WARNING: When the Counter-Clockwise box is checked, the normal direction of rotation
is opposite from what is indicated by the label of the Reverse switch on the tool.
If a sequence has not been selected for a stage, then N/A is displayed for that stage. Otherwise
the Sequence number, description and icon are displayed. Sequences can be selected using the
Select Seq <F1> soft key. This key is only valid when stages 1-6 are highlighted. The Fastening
Sequence for the Backoff Stage is selected automatically.
The parameters for any stage can be programmed using the Parameters <F3> soft key. This key
is only valid when a Sequence has been selected for a given Stage.