en03d141.fm, 11.03.2008
PL12EN-1300 2008-03
31
Programming
3
3.3.3
Standard Application Builder / Select Sequence
c0
02
81
en.
bm
p
Fig. 3-8: Select Sequence
selectse.txtS
Fastening Sequences are selectable for a given Tool, Application and Stage by using the Control
and Monitor check boxes or selecting a Fastening Sequence directly from the drop down listbox.
The following Fastening Sequences or Fastening Strategies are available:
Sequence 41 or Sequence 46
Backoff using Reverse switch/Relax
Sequence 11
High Speed Rundown
Sequence 30
Torque Control/Angle Monitor
Sequence 50
Angle Control/Torque Monitor
Sequence 41
Angle Controlled Backoff
When a Sequence is selected the Control and Monitor check boxes and Fastening Sequence
listbox will both display the appropriate settings for the selected Sequence. An icon portraying
the selected Sequence is also displayed in the bottom right-hand corner.
The following table shows a matrix of the Control and Monitor schemes for each Sequence:
Sequence 11
Sequence 30
Sequence 50
Sequence 41
Control
Torque Control
X
X
Angle Control
X
Angle Control Reverse
X
Monitor
Torque Monitor
X
X
Angle Monitor
X
X
X
The Parameters <F3> soft key allows the user to program all associated control parameters for
the selected Sequence. It is only valid when a Sequence has been selected.