16
PL12EN-1300 2008-03
en02d141.fm, 11.03.2008
Controller Specifications
2
Arcnet PC/104 board
• Arcnet communication
• 4 +24 V inputs
• 12 +24 V outputs
• 24-position keypad decoder
• Battery-Backed SRAM, 1 MB
External I/O PC/104 board
• 8 optically isolated inputs
• 8 relay outputs
2.2.6
AC Input Power
• Selectable 115 VAC @15 A or 230 VAC @ 10 A, +/-5% on all voltages. External fuse should
be slow blow.
• Internal fuse
• Fault current circuit-breaker (10 mA)
• Isolation Transformer 4.5 kVA peak, meets VDA 0570 norm
Note: If necessary it's possible to connect two units to one 230 VAC power supply with a 16 A
slow blow fuse (C-Type).
2.2.7
Inernal DC Power
• Input: 85 VAC-264 VAC
• Output: +5 VDC @ 5 A, +12 VDC @ 1 A, +24 VDC @ 3 A, +/-5% on all voltages
• 110 W capability without a fan
• MTBF->20,000 hours
2.2.8
Input / Output Connectors
Tool Connector
Matrix MS83723R/2028N
Serial (2)
9-pin Male D-Shell
Parallel
25-pin Female D-Shell
Keyboard
Mini 6-DIN
Inputs (+24 V)
Phoenix MSTBV 2,5/12-GF-5,08 Order No. 1777170
Outputs
Phoenix ICV 2,5/12-GF-5,08 Order No. 1825792
Floppy
3.5in 1.44 MB
AC Power Input
Standard male receptacle
AC Power Output
Standard female receptacle