en03d141.fm, 11.03.2008
Programming
3
pressed and when the diagnostics menu is exited. The state of all signals will remain intact when
other menu tabs are selected.
This feature may not be activated from TM-COM except for TMEM.
diafield.txtE
3.11.3
Tool / Calibration
c00
2
99
en
.bmp
Fig. 3-43: Tool / Calibration
testcali.txtS
This test function cyclically recalibrates the system with the values used immediately before the
start of a rundown. The spindle must be released for this function! The values "Offset Voltage"
and "Full Scale Voltage" of the torque transducer are displayed. If redundancy is activated, the
values of the second transducer are displayed. If a value is out of tolerance, it is shown in red.
Rated values and tolerances:
Value
Rated value
Tolerance
Calibration offset:
0 V
+/-200 mV
Calibration voltage:
5 V
+/-150 mV
Note:
Entering a password and viewing of a warning is required prior to running any "active"
tool diagnostics.
Note:
Not available on the TMEI.
testcali.txtE