Programming
3
Ethernet
Protocol
None, Standard, PFCS, FEP
The ethernet settings include:
• Server IP Address
• Gateway
• Host
• Subnet Mask
• Port Address
The MAC address of the ethernet interface is displayed for informational purposes only and is
not configurable. See your network administrator for proper settings. To enable communications
with TM-COM, the IP address of for TM Unit, Gateway, and Subnet must be entered. For further
protocol descriptions contact a Technical Service Representative in Customer Satisfaction.
(2-Channel V2.xx.xx C2 only). When the ethernet "Standard" protocol is selected, there is one
connection made per controller. For all messages containing a "Station Number", the station
number for tool 1 is used. For the Rundown packet (#4), the "Spindle Number" field is 1 or 2
depending on the associated tool. Refer to Engineering Specification 543027 "Network Software
Specification" for more information.
commdata.txtE
3.7.2
Communication / Part ID
c004
05
en
.bm
p
Fig. 3-27: Part ID
comprtid.txtS
The Part ID configuration screens allow the user to specify the interface and functionality of the
Part ID used on the Run Screen and archived with the rundown data. Changes to the Part ID and
Configuration Data edit screens are saved when the “Communications” screen is exited (Run
Screen or Navigator button pressed). At this time the request to save the configuration is con-
firmed with a password dialog box.
The Part ID may be entered manually from the run screen, input using a barcode reader attached
to a serial port, or transmitted through a FieldBus. A Part ID may consist of any sequence of
Alphanumeric characters, including spaces.