Programming
3
Field Bus Configuration
Node Address
Defines the address of the TME controller. DeviceNet (1-63),
Profibus (2-125), Ethernet/IP uses the controller IP address
configured in Communications / Data Transmission.
Baud Rate
Defines the rate at which information is sent/received from the
TME controller. For DeviceNet three choices are available:
500KBits, 250 KBits, or 125 KBits. The rate should be set to
match the fieldbus system available. For Profibus and Ether-
net/IP, this option is not available. The Baud Rate is automati-
cally set to the master settings.
Part ID
A checked box enables the Part ID function.
Disable on disconnect
A checked box that disables further rundowns and displays a
"Check Cable" Message on Run Screen as long as the field-
bus doesn't work.
Format
Determines how the 32-bit Part ID is converted into readable
characters. When "Decimal" is selected, the resulting Part ID
is 10 characters in length. When "Hexadecimal" is selected,
the resulting Part ID is 8 characters in length.
Tool 2 Control
A checked box enables an alternate format for word 1 byte 0 of
the fieldbus outputs that replaces the standard Torque/Angle
results outputs with Cycle OK, Cycle NOK, and "yellow light"
outputs that originate from tool 2.
Dwell Time
This is the number of milliseconds that each fieldbus output bit
will stay on or off immediately after a state change. The stan-
dard range is 50 to 999 milliseconds.
Enable I/O Configuration
This section allows the user to control the information sent/received in the data stream. Inputs
and Outputs can be individually enabled.
Inputs
Appl. Select (1-8)
Allows the fieldbus to control the Application selected from 1
to 8
Reset Linking
Allows the fieldbus to reset the linking to the first position
Remote Tool Start
Allows the fieldbus to start the tool
Remote Tool Reverse
Allows the fieldbus to control the rotation direction
Tool Ready
Allows the fieldbus to blink the yellow LED on the tool
Tool Enable
Allows the fieldbus to enable/disable the tool
Appl. Select (9-255)
Allows the fieldbus to control the Application selected 1 to
255. This can only be enabled if Appl. Select (1-8) is set
Socket Tray Lamp
Select (1-8)
Allows the fieldbus to control the Socket Tray Lamp Select,
and enables the "Socket Tray Lamps Enable" input.
Outputs
Linking Outputs
Output data will include linking OK, NOK, and Complete
Appl. Select (1-8)
Output data will include current Application selection 1-8