doseBadge⁵ noise dosimeter - instrument handbook
57
• Up to five pages of measured acoustic values. Which value is displayed depends on
the settings of the measurement channels on the badge, and can be modified using
NoiseTools. Available values include LAeq, LCPeak, exposure, estimated exposure, and
dose.
A red triangle is shown in the top-right corner of all those pages if an overload occurred
during the measurement.
Note that the “Review” page stays accessible, even after disconnecting from your doseBadge.
15.3.5.1 Measurement summary
This page displays the number of the measurement, the start date and time, and the
measurement duration. If your doseBadge is currently measuring, the measurement
number is replaced with a “Recording” symbol to indicate that this measurement is currently
in progress.
15.3.5.2 Calibration status
This page shows the details of the last calibration done before the measurement started.
15.3.5.3 Acoustic values
These pages display the measured acoustic values. There are three page templates:
The “Integrator template” contains the name of the integrator (e.g.
ISO, OSHA PEL, ACGIH, etc.) and two acoustic values (e.g LAeq,
Lavg, TWA, exposure, dose, etc.).