EM11 User’s Manual
Appendix II
149
Code
Parameter Name
Setting range
Default
Property
b3-08
DI9 function
selection(extend)
38: Normally open (NO) input of external
fault
39: Normally closed (NC) input of external
fault
40: User-defined fault 1
41: User-defined fault 2
42: Running pause
43: Free stop
44: Emergency stop
45: External STOP terminal 1
46: External STOP terminal 2
47: Deceleration DC braking
48: Immediate DC braking
49: Clear the current running time
0
★
b3-09
DI10 function
selection(extend)
0
★
b3-10
DI11 function
selection(extend)
(extend)
0
★
b3-11
DI12 function
selection(extend)
0
★
b3-12 DI
filter
time
0.000s~1.000s
0.010s
☆
b3-13
Terminal command
mode
0: Two-line mode 1
1: Two-line mode 2
2: Three-line mode 1
3: Three-line mode 2
0
★
b3-14
Terminal UP/DOWN
rate
0.001Hz/s~65.535 Hz/s
0.100 Hz/s
☆
b3-15
DI1 ON delay time
0.0s~3000.0s
0.0s
☆
b3-16
DI1 OFF delay time 0.0s~3000.0s
0.0s
☆
b3-17
DI2 ON delay time
0.0s~3000.0s
0.0s
☆
b3-18
DI2 OFF delay time 0.0s~3000.0s
0.0s
☆
b3-19
DI3 ON delay time
0.0s~3000.0s
0.0s
☆
b3-20
DI3 OFF delay time 0.0s~3000.0s
0.0s
☆
b3-21
DI4 ON delay time
0.0s~3000.0s
0.0s
☆
b3-22
DI4 OFF delay time 0.0s~3000.0s
0.0s
☆
b3-23
DI5 ON delay time
0.0s~3000.0s
0.0s
☆
b3-24
DI5 OFF delay time 0.0s~3000.0s
0.0s
☆
b3-25
DI valid selection 1
Unit's digit: DI1 valid mode.
0: Low level valid
1: High level valid
Ten's digit: DI2 valid mode.
0, 1 (same as DI1)
Hundred's digit: DI3 valid mode.
0, 1 (same as DI1)
Thousand's digit: DI4 valid mode.
0, 1 (same as DI1)
Ten thousand's digit: DI5 valid mode.
0, 1 (same as DI1)
00000
★
Appendix II
EM11 User’s Manual
150
Code
Parameter Name
Setting range
Default
Property
b3-26
DI valid selection 2
Unit's digit: DI6 valid mode.
0, 1 (same as DI1)
Ten's digit: DI7 valid mode.
0, 1 (same as DI1)
Hundred's digit: DI8 state.
0, 1 (same as DI1)
Thousand's digit: DI9 valid mode.
0, 1 (same as DI1)
Ten thousand's digit: DI10 valid mode.
0, 1 (same as DI1)
00000
★
b3-27
DI valid selection 3
Unit's digit: DI11 valid mode.
0, 1 (same as DI1)
Ten's digit: DI12 valid mode.
0, 1 (same as DI1)
00
★
Group b4: Switch Signal output Terminals
b4-00
FM terminal output
mode
0: Pulse output (FMP)
1: Switch signal output (FMR)
1
☆
b4-01
FMR function (open-
collector output
terminal)
0: No output
1: Ready signal
2: Frequency inverter running
3: Fault output (free stop fault)
4: Fault output (free stop fault, but do not
output when lower voltage)
5: Swing frequency limit
6: Torque limit
7: Frequency upper limit reached
8:Frequency lower limit reached (relevant to
running)
9: Frequency lower limit reached (having
output at stop)
10: Reverse running
11: Zero-speed running (no output at stop)
12: Zero-speed running 2 (having output at
stop)
13: Preset count value reached
14: Designated count value reached
15: Length reached
16: PLC cycle complete
17: Frequency-level detection FDT1 output
18: Frequency level detection FDT2 output
19: Frequency reached
20: Frequency 1 reached
21: Frequency 2 reached
22: Current 1 reached
23: Current 2 reached
24: Module temperature reached
25: Timing reached
0
☆
b4-02
Relay 1 function
(TA-TB-TC)
2
☆
b4-03 Reserved
☆
b4-04
DO1 function selection
(open-collector output
terminal)
1
☆
b4-05 DO2
function(extend)
0
☆