EM11 User’s Manual
5. Description of Function Codes
123
0:No operation
1: Restore default settings except motor parameters
If A0-09 is set to 1, most function codes are restored to the default settings
except
motor parameters,
frequency command resolution (b0-11), fault records, accumulative running time (b9-09), accumulative
power-on time (b9-08) and accumulative power consumption (b9-10).
2: Restore default settings for all parameters, including motor parameters
3: Restore user backup parameters
If A0-09 is set to 3, the previous backup user parameters are restored (backup by setting A0-09=999).
4: Clear records
If A0-09 is set to 4, the fault records, accumulative power-on time (b9-08), accumulative running time
(b9-09), and accumulative power consumption (b9-10) are cleared.
999: Back up present user parameters
If A0-09 is set to 999, the present parameter settings are backed up, helping you to restore the setting if
incorrect parameter setting is performed.
5.25 Group A1: User-Defined Function Codes
Code
Parameter Name
Setting Range
Default
A1-00
User-defined function
code 0
User visible function codes
ub0.01
A1-01
User-defined function
code 1
User visible function codes
ub0.02
A1-02
User-defined function
code 2
User visible function codes
ub0.03
A1-03
User-defined function
code 3
User visible function codes
ub0.07
A1-04
User-defined function
code 4
User visible function codes
ub0.12
A1-05
User-defined function
code 5
User visible function codes
ub0.21
A1-06
User-defined function
code 6
User visible function codes
ub0.22
A1-07
User-defined function
code 7
User visible function codes
ub3.00
A1-08
User-defined function
code 8
User visible function codes
ub3.01
A1-09
User-defined function
code 9
User visible function codes
ub3.02
A1-10
User-defined function
code 10
User visible function codes
ub4.04
A1-11
User-defined function
code 11
User visible function codes
ub6.01
A1-12
User-defined function
code 12
User visible function codes
ub1.00
A1-13
User-defined function
code 13
User visible function codes
ub1.10
A1-14
User-defined function User visible function codes
ud2.00
5. Description of Function Codes
EM11 User’s Manual
124
Code
Parameter Name
Setting Range
Default
code 14
A1-15
User-defined function
code 15
User visible function codes
ud2.01
A1-16
User-defined function
code 16
User visible function codes
uA0.00
A1-17
User-defined function
code 17
User visible function codes
uA0.00
A1-18
User-defined function
code 18
User visible function codes
uA0.00
A1-19
User-defined function
code 19
User visible function codes
uA0.00
A1-20
User-defined function
code 20
User visible function codes
uA0.00
A1-21
User-defined function
code 21
User visible function codes
uA0.00
A1-22
User-defined function
code 22
User visible function codes
uA0.00
A1-23
User-defined function
code 23
User visible function codes
uA0.00
A1-24
User-defined function
code 24
User visible function codes
uA0.00
A1-25
User-defined function
code 25
User visible function codes
uA0.00
A1-26
User-defined function
code 26
User visible function codes
uA0.00
A1-27
User-defined function
code 27
User visible function codes
uA0.00
A1-28
User-defined function
code 28
User visible function codes
uA0.00
A1-29
User-defined function
code 29
User visible function codes
uA0.00
A1-30
User-defined function
code 30
User visible function codes
uA0.00
A1-31
User-defined function
code 31
User visible function codes
uA0.00
Group A1 is user-defined parameter group. You can select the required parameters from all EM11 functions
codes and add them into this group, convenient for view and modification.
Group A1 provides a maximum of 32 user-defined parameters. If "A1-00" is displayed, it indicates that
group A1 is null. After you enter user-defined function code mode, the displayed parameters are defined by
A1-00~ A1-31 and the sequence is consistent with that in group A1.