EM11 User’s Manual
Appendix II
165
Code
Parameter Name
Setting range
Default
Property
switchover deviation 2
C0-15
PID integral property
Unit's digit: Integral separated.
0: Invalid
1: Valid
Ten's digit: Whether to stop integral
operation when the output reaches the limit.
0: Continue integral operation
1: Stop integral operation
00
☆
C0-16
PID initial value
0.0%~100.0%
0.0%
☆
C0-17
PID initial value
holding time
0.00s~650.00s 0.00s
☆
C0-18
Frequency upper limit
of PID reverse rotation
0.00 ~ maximum frequency
2.00 Hz
☆
C0-19 PID
deviation
limit
0.0%~100.0%
0.0%
☆
C0-20
PID differential limit 0.00%~100.00%
0.10%
☆
C0-21
Maximum positive
deviation between two
PID outputs
0.00%~100.00% 1.00%
☆
C0-22
Maximum negative
deviation between two
PID outputs
0.00%~100.00% 1.00%
☆
C0-23 PID feedback filter time 0.00s~60.00s
0.00s
☆
C0-24
PID output filter time 0.00s~60.00s
0.00s
☆
C0-25
Detection value of PID
feedback loss
0.0%: Not judging feedback loss
0.1%~100.0%
0.0%
☆
C0-26
Detection time of PID
feedback loss
0.0s~20.0s 0.0s
☆
C0-27
PID operation at stop
0: No PID operation at stop
1: PID operation at stop
0
☆
Group C1: Multi-function
C1-00 Multi-function
0
-100.0%~100.0%
0.0%
☆
C1-01 Multi-function
1
-100.0%~100.0%
0.0%
☆
C1-02 Multi-function
2
-100.0%~100.0%
0.0%
☆
C1-03 Multi-function
3
-100.0%~100.0%
0.0%
☆
C1-04 Multi-function
4
-100.0%~100.0%
0.0%
☆
C1-05 Multi-function
5
-100.0%~100.0%
0.0%
☆
C1-06 Multi-function
6
-100.0%~100.0%
0.0%
☆
C1-07 Multi-function
7
-100.0%~100.0%
0.0%
☆
C1-08 Multi-function
8
-100.0%~100.0%
0.0%
☆
C1-09 Multi-function
9
-100.0%~100.0%
0.0%
☆
C1-10 Multi-function
10
-100.0%~100.0%
0.0%
☆
C1-11 Multi-function
11
-100.0%~100.0%
0.0%
☆
C1-12 Multi-function
12
-100.0%~100.0%
0.0%
☆
C1-13 Multi-function
13
-100.0%~100.0%
0.0%
☆
C1-14 Multi-function
14
-100.0%~100.0%
0.0%
☆
C1-15 Multi-function
15
-100.0%~100.0%
0.0%
☆
C1-16 Multi-function 0 source 0: Set by C1-00
0
☆
Appendix II
EM11 User’s Manual
166
Code
Parameter Name
Setting range
Default
Property
1: AI1
2: AI2
3: AI3
4: Pulse setting(DI6)
5: PID
6: Set by preset frequency (b0-12), modified
via terminal UP/ DOWN
Group C2: Simple PLC
C2-00
Simple PLC running
mode
0: Stop after the Frequency inverter runs one
cycle
1: Keep final values after the frequency
inverter runs one cycle
2: Repeat after the frequency inverter runs
one cycle
0
☆
C2-01
Simple PLC record
selection
Unit's digit: Record of power failure.
0: no record after power off
1: record after power off
Ten's digit: Record of stopping.
0: no record after stopping
1:record after stopping
00
☆
C2-02
Running time of simple
PLC Segment 0
0.0s(h)~6553.5s(h) 0.0s
(h)
☆
C2-03
Acceleration/deceleratio
n time of simple PLC
Segment 0
0~3 0
☆
C2-04
Running time of simple
PLC Segment 1
0.0s(h)~6553.5s(h) 0.0s
(h)
☆
C2-05
Acceleration/deceleratio
n time of simple PLC
Segment 1
0~3 0
☆
C2-06
Running time of simple
PLC Segment 2
0.0s(h)~6553.5s(h) 0.0s
(h)
☆
C2-07
Acceleration/deceleratio
n time of simple PLC
Segment 2
0~3 0
☆
C2-08
Running time of simple
PLC Segment 3
0.0s(h)~6553.5s(h) 0.0s
(h)
☆
C2-09
Acceleration/deceleratio
n time of simple PLC
Segment 3
0~3 0
☆
C2-10
Running time of simple
PLC Segment 4
0.0s(h)~6553.5s(h) 0.0s
(h)
☆
C2-11
Acceleration/deceleratio
n time of simple PLC
Segment 4
0~3 0
☆
C2-12
Running time of simple
PLC Segment 5
0.0s(h)~6553.5s(h) 0.0s
(h)
☆