Single Site
Quantum Maestro Getting Started Guide | 85
Important:
n
After you connect a breakout cable to port 31, the Dual Site External
Synchronization works on the 4th split of this port:
l
On the first Orchestrator -
Port 1/31/4
l
On the second Orchestrator -
Port 2/31/4
n
After you connect a breakout cable to port 32, the Single Site Internal
Synchronization works on the 4th split of this port:
l
On the first Orchestrator -
Port 1/32/4
l
On the second Orchestrator -
Port 2/32/4
MHO-170 Splitting Options
It is possible to split only the top QSFP28 odd ports 1 to 29 (colored green) into four SFP28 ports, each.
When the top odd ports 1 to 29 (colored green) are in split mode, the corresponding bottom QSFP28 even
ports 2 to 30 are disabled (colored red).
Important - It is not supported to connect a breakout cable to Port
31
because it
disables the dedicated synchronization Port
32
.
After you connect breakout cables to the top ports, you get
four
additional interfaces starting from the
original interface name. You assign these interfaces to Security Groups.
Example - When you connect a breakout cable to the top port 15 (interface "
eth1-29
"), you get:
Port
Number
on the
Front
Panel
Interface
Name
in Gaia OS
Port
Name
in Gaia OS
15
eth1-29
Port 1/15/1
eth1-30
Port 1/15/2
eth1-31
Port 1/15/3
eth1-32
Port 1/15/4
Note - For more information about the ports and interface names in Gaia, see
Orchestrator Ports and Gaia OS Interfaces" on page 170
.