Dual Site with Direct Connection
Quantum Maestro Getting Started Guide | 133
Explanations
Item
Description
1
DAC cables, Fiber cables (with transceivers), or Breakout cables that connect Downlink
ports on the
first
Quantum Maestro Orchestrator (
3
) on the
first
site to the Security
Appliance (
17
,
19
and
22
) on the
first
site.
These cables connect to the
odd
port of an Expansion Line Card on Security Appliances.
2
The dedicated external synchronization port (Port 47) on the
first
Quantum Maestro
Orchestrator (
3
) on the
first
site.
This port connects with a DAC cable or Fiber cable (with transceivers) to the dedicated
external synchronization port (5) on the
first
Quantum Maestro Orchestrator (
6
) on the
second
site.
3
The
first
Quantum Maestro Orchestrator on the
first
site.
4
DAC cables, Fiber cables (with transceivers), or Breakout cables that connect Downlink
ports on the
first
Quantum Maestro Orchestrator (
6
) on the
second
site to the Security
Appliance (
18
,
21
and
23
) on the
second
site.
These cables connect to the
odd
port of an Expansion Line Card on Security Appliances.
5
The dedicated external synchronization port (Port 47) on the
first
Quantum Maestro
Orchestrator (
6
) on the
second
site.
This port connects with a DAC cable or Fiber cable (with transceivers) to the dedicated
external synchronization port (2) on the
first
Quantum Maestro Orchestrator (3) on the
first
site.
6
The
first
Quantum Maestro Orchestrator on the
second
site.
7
The dedicated internal synchronization port (Port 48) on the
first
Quantum Maestro
Orchestrator (
3
) on the
first
site.
This port connects with a DAC cable to the dedicated internal synchronization port (15) on
the
second
Quantum Maestro Orchestrator (
11
) on the
first
site.
Important:
n
This connection is only used to synchronize the configuration of Security
Groups between the Quantum Maestro Orchestrators.
n
MHO-175 and MHO-170 require a 100 GbE DAC or 40 GbE DAC cable.
n
MHO-140 requires a 10 GbE DAC cable.
8
The dedicated internal synchronization port (Port 48) on the
first
Quantum Maestro
Orchestrator (
6
) on the
second
site.
This port connects with a DAC cable to the dedicated internal synchronization port (16) on
the
second
Quantum Maestro Orchestrator (
14
) on the
second
site.
Important:
n
This connection is only used to synchronize the configuration of Security
Groups between the Quantum Maestro Orchestrators.
n
MHO-175 and MHO-170 require a 100 GbE DAC or 40 GbE DAC cable.
n
MHO-140 requires a 10 GbE DAC cable.
Table: Explanations