Select a TeraStation to be the backup destination device and enter its administrator username and password
(the username is "admin", the password is "password" by default).
5
Select the LAN port to be used for sharing files and enter a virtual IP address and subnet mask.
About Virtual IP Address:
A virtual IP address is an IP address that will be used for file sharing while failover is configured. By assigning
a different IP address from the one to be assigned to the LAN port, you can access the TeraStation for sharing
files, as well as open Settings using the virtual IP address. This IP address will be inherited to the backup
TeraStation when failover occurs, so you can access the backup TeraStation even if you don't know the backup
TeraStation's static IP address.
Configure an unused IP address for the virtual IP; make sure it uses the same segment as the main and backup
TeraStations.
6
Select the LAN port to be used for transferring data via failover, then click
Continue
.
7
If the administrator username and password is correct, the backup TeraStation will beep. Press and hold the
function button to accept the settings from the main TeraStation. When you press the function button, the
backup TeraStation will stop beeping. Hold it down until the backup TeraStation beeps again.
8
The I51 message will display on the LCD panel and NAS Navigator2 for both TeraStations. Wait until
initialization finishes. Failover is configured after it finishes and the I51 message disappears.
Notes:
• If replication is configured for more than one folder, initialize the TeraStation before configuring failover.
• The main TeraStation cannot be used as the backup location for Time Machine.
• Do not use the same TeraStation for both failover and replication, or failover and Time Machine.
• If email notification is enabled and failover occurs, navigate to
Management
-
Email Notification
-
Edit
in the
main TeraStation's Settings and click
OK
.
• Ethernet frame size settings for main and backup TeraStations should be 1500 bytes. To change the Ethernet
frame size, navigate to
Network
-
IP Address
-
Edit
, and change the Ethernet frame size to "1500" bytes.
• Files whose filenames contain more than 80 alphanumeric characters will not be backed up.
• If the I33 error message appears on the LCD panel, navigate to
Backup
-
Replication
and click
Resync
.
Summary of Contents for TeraStation 5010
Page 8: ...7 For Customers in Taiwan 175 ...
Page 75: ...74 3 Click Edit 4 Click Add 5 Click Browse under Replication Source ...
Page 87: ...86 18Click Time Machine ...
Page 88: ...87 19Click Select Backup Disk 20Select the TeraStation then click Use Disk ...
Page 97: ...96 3 Click Create New Job 4 Select backup settings such as date and time to run 5 Click Add ...
Page 103: ...102 4 Click the Options tab 5 Click Edit ...
Page 137: ...136 3 Click Edit ...
Page 138: ...137 4 Select or enter the desired MTU size and click OK ...