109
5
In Settings, click
Management
.
6
Click
to the right of "Power Management".
7
Click
Edit
.
8
Configure the desired settings, then click
OK
.
Notes:
• If the TeraStation is connected directly to a UPS, select "Sync with UPS connected to this TeraStation". If a
different TeraStation is connected to the UPS, select "Sync with UPS connected to another LinkStation or
TeraStation on the same network". After making this selection, enter the IP address of the TeraStation that will
be the sync source in "Other LinkStation or TeraStation's IP Address".
• If you don't want to connect any UPS, select "Do not synchronize with UPS" and the operation when a power
supply failure occurs. If "Use last state" at "AC Power Recovery" is selected, the TeraStation will revert to the
state before the power supply failure occurs. If "Stay off" is selected, the TeraStation will keep off even after
the TeraStation shuts down due to the power supply failure.
• When the TeraStation is restarted after an automatic shutdown such as from a power outage or power supply
problem, verify that the power supply has been restored. If the TeraStation is turned on while it is still running
on the UPS and without the power supply restored, automatic shutdown is not performed, even after the
specified time has elapsed.
• If the power supply from the UPS to the TeraStation is stopped and restarted when UPS recovery is enabled,
the TeraStation is automatically restarted.
• The "UPS sends low battery signal" will be grayed out when the UPS is connected to the TeraStation using a
USB-to-serial converter cable.
Summary of Contents for TeraStation 5010
Page 8: ...7 For Customers in Taiwan 175 ...
Page 75: ...74 3 Click Edit 4 Click Add 5 Click Browse under Replication Source ...
Page 87: ...86 18Click Time Machine ...
Page 88: ...87 19Click Select Backup Disk 20Select the TeraStation then click Use Disk ...
Page 97: ...96 3 Click Create New Job 4 Select backup settings such as date and time to run 5 Click Add ...
Page 103: ...102 4 Click the Options tab 5 Click Edit ...
Page 137: ...136 3 Click Edit ...
Page 138: ...137 4 Select or enter the desired MTU size and click OK ...