Fault
Cause and troubleshooting
Dishes frequently boil
over.
Precise temperature is
not attained.
Sea level is not set correctly.
▶
Set the correct sea level.
→
Temperature is too high.
▶
Reduce the temperature.
→
"What is the best way to proceed?", Page 130
SensorSpot or infrared temperature sensor is soiled.
▶
Clean the SensorSpot.
▶
Clean the infrared temperature sensor.
→
"Cleaning the main unit", Page 121
SensorSpot is missing.
▶
Re-order the SensorSpot from customer service us-
ing the service number 10012160.
Infrared temperature sensor is scratched.
▶
Contact our Customer Service.
Total quantity is too low.
▶
Add ingredients until above the marking .
Measuring cup is not used correctly.
▶
Note the information on use of the lid.
→
"Overview of using the lid", Page 98
Tool cannot be inser-
ted.
Tool is soiled inside.
▶
Clean the tool.
→
"Overview of cleaning", Page 118
Spring washer is missing.
▶
Fit the spring washer.
An odour develops in
the appliance.
Appliance is used for the first time or is under a high
load.
Note:
Odour development is normal and harmless.
Vapours develop when cooking food.
▶
If you are not using the appliance, remove the
measuring cup.
Note:
Odour development is normal and harmless.
Lid is leaking.
Lid or lid seal is faulty.
1.
Check the lid and lid seal for faults.
2.
If the lid or lid seal is faulty, contact customer ser-
vice.
Pot is leaking.
Silicone seal ring on the tool holder is missing.
▶
Insert the silicone seal ring.
→
Summary of Contents for MCC9555FWC
Page 14: ...fr Installation et branchement 14 A B C D E F G H I J K L M N O ...
Page 19: ...Description de l appareil fr 19 1 5 12 6 7 8 9 10 15 18 19 20 21 22 17 13 2 3 4 16 14 11 ...
Page 81: ...en 81 26 16 Braising 148 26 17 Searing 148 ...
Page 90: ...en Installation and connection 90 A B C D E F G H I J K L M N O ...