panel and move or wiggle wires
while observing meter. Continue to
move down harness until meter
displays a reading. This is the
location of short to ground.
-
Visually inspect wire harness at
this point for any faults. If no faults
are visible, carefully slice open
harness cover or wire insulation
for further inspection. Repair any
faults found.
Short circuit, testing with
voltmeter
-
Remove blown fuse from circuit.
Disconnect harness connector
from circuit load or consumer.
Note:
Most fuses power more than one
consumer. Be sure all consumers are
disconnected when checking for a short
circuit.
Using a digital multimeter, connect test
leads across fuse terminals. Make sure
power is present in circuit. If necessary
turn key on.
-
If voltage is present at voltmeter,
there is a short to ground.
-
If voltage is not present, work from
wire harness nearest to fuse/relay
panel and move or wiggle wires
while observing meter. Continue to
move down harness until meter
displays a reading. This is the
location of short to ground.
-
Visually inspect wire harness at