BMW
code
P-code
Fault type and
function
Signal type and
range
Explanation
disconnection between output
transistor and component
exists.
124
P1593
DISA, range/perf.
Output digital
on/off (active low)
DME final stage will set flag
whenever a short to ground, a
short to battery voltage or a
disconnection between output
transistor and component
exists.
125
Coolant fan, final
stage
Output digital
on/off (active low)
DME final stage will set flag
whenever a short to ground, a
short to battery voltage or a
disconnection between output
transistor and component
exists.
126
P1470
MS 42
LDP-magnetic
valve
Output digital
on/off (active low)
DME final stage will set flag
whenever a short to ground, a
short to battery voltage or a
disconnection between output
transistor and component
exists.
MS 43
DMTL valve
Output digital
on/off (active low)
DME final stage will set flag
whenever a short to ground, a
short to battery voltage or a
disconnection between output
transistor and component
exists.
127
Fuel pump
Output digital
on/off (active low)
DME final stage will set flag
whenever a short to ground, a
short to battery voltage or a
disconnection between output
transistor and component
exists.
128
EWS signal not
present or faulty
Input binary
stream bit data
(0-12V)
During time out check no
signal was present within
specific time or faulty
information from serial
interface (parity, overrun,
etc.).
130
CAN time out
(ASC1)
Input binary
stream bit data
(0-12V)
CAN message between
DME/EGS not received within
expected time.
On-Board Diagnostics
http://ebahn.bentleypublishers.com/BMW/3/E46/Repair%20Manuals/8...
10 of 20
2/25/2009 11:23 PM
Summary of Contents for 1999-2005 M3
Page 1: ......