Good grounds are critical to proper
DME operation. If a ground connection
has no visible faults but is still suspect,
measure the voltage drop across the
connection. A large voltage drop
indicates high resistance, indicating
that the connection is corroded, dirty or
damaged. Clean or repair the
connection and retest.
Note:
For instructions on conducting a voltage
drop test and other general electrical
troubleshooting information, see
600
Electrical System–General
.
Below is a listing of the main grounds
for the fuel and ignition circuits of the
DME system.
Main ground (
arrow
) for engine
management system in left rear of
engine compartment on bulkhead
behind E-box.
Main grounds for ignition coils
(
arrows
).
Main chassis ground harness
connection (
arrow
) in left front of
Engine-General