BMW
code
P-code
Fault type and
function
Signal type and
range
Explanation
spring within motor throttle
body.
110
P1542
Pedal sensor
potentiometer 1
Input analog
(0-5V)
Failed signal range check
against predefined diagnostic
limits.
111
P1542
Pedal Sensor
Potentiometer 2
Input analog
(0-5V)
Failed signal range check
against predefined diagnostic
limits.
112
P0120
MS 42
Motor throttle valve
potentiometer 1
Input analog
(0-5V)
Failed signal range check
against predefined diagnostic
limits.
MS 43
Throttle position
sensor 1
Input analog
(0-5V)
Failed signal range check
against predefined diagnostic
limits.
113
P0120
Motor throttle valve
potentiometer 2
Input analog
(0-5V)
Failed signal range check
against predefined diagnostic
limits.
114
P1580
MS 42
Motor throttle valve
final stage
DME internal test
Final stage inside DME
(special H-bridge), will set
internal flag whenever a short
to ground, a short to battery
voltage or a disconnection
occurs.
MS 43
A second pedal
sensor range
check failure is
determined
DME internal
values logical
If pedal sensor malfunction is
determined, followed by a
second malfunction, a signal
is sent.
115
P1623
MS 42
Output voltage 5V
for potentiometer
operation 1
DME internal (5V)
Check for proper 5 volts
supply to potentiometers is
possible within a predefined
voltage limit.
MS 43
Range check for
throttle position
adaptation
Input analog
(0-5V)
Range check for closed
position of throttle sensors.
116
P1623
Output voltage for
potentiometer
operation 2
DME internal (5V)
Check for proper 5 volts
supply to potentiometers is
possible within a predefined
voltage limit.
On-Board Diagnostics
http://ebahn.bentleypublishers.com/BMW/3/E46/Repair%20Manuals/8...
8 of 20
2/25/2009 11:23 PM
Summary of Contents for 1999-2005 M3