Table b. Temperature sensor
resistance values at 25°C (77°F)
Sensor
Resistance
Fault
limit
125°C
(257°F)
Evaporator
9 k
± 2%
Temp >
120°C
(248°F)
Interior
10 k
± 2%
Temp ≤
-46°C
(-51°F)
Table c
lists A/C evaporator
temperature-dependent resistance
values.
Table c. A/C evaporator temperature
sensor resistance values
Temperature
°C/°F
Resistance
range
k
-5/23
11.7 - 11.9
0/32
8.8 - 9.2
5/41
6.8 - 7.2
10/50
5.3 - 5.6
15/59
4.2 - 4.5
20/68
3.3 - 3.6
25/77
2.6 - 2.9
30/86
2.1 - 2.3
35/95
1.7 - 1.9
Table d
lists A/C expansion valve
pressure values.
Table d. Expansion valve pressure
values