battery voltage), a fuse will blow and
the circuit may possibly be damaged.
Shorts to ground can be located with a
digital multimeter. Short circuits are
often difficult to locate and may vary in
nature. Short circuits can be found
using a logical approach based on
current path.
CAUTION!
On circuits protected with high
rating fuses (25 amp and
greater), wires or circuit
components may be damaged
before the fuse blows. Always
check for damage before
replacing fuses of this rating.
When replacing blown fuses,
use only fuses having the
correct rating. Always confirm
the correct fuse rating printed
on the fuse/relay panel cover.
Short circuit, testing with
ohmmeter
-
Remove blown fuse from circuit
and disconnect cables from
battery. Disconnect harness
connector from circuit load or
consumer.
Using an ohmmeter, connect one test
lead to load side of fuse terminal
(terminal leading to circuit) and the
other test lead to ground.
-
If there is continuity to ground,
there is a short to ground.
-
If there is no continuity, work from
wire harness nearest to fuse/relay