Using a clean syringe, empty
brake fluid reservoir.
WARNING!
Brake fluid is highly corrosive and
dangerous to the environment.
Dispose of it properly.
Remove interior ventilation microfilter
housing.
Remove upper cover and
microfilter.
Open wiring harness loom (
A
) and
remove wires.
Unfasten screws (
B
) and remove
lower microfilter housing.
Remove side trim panel from left rear of
engine compartment:
Remove rubber strip (
A
) from top
of trim panel at brake booster.
Remove vacuum line and positive
battery cable with grommets (
B
)
from trim panel.
Release locking clips (
C
) on
edges of trim panel and remove
panel by pulling upwards.
Working at precharge pump beneath
brake master cylinder:
Remove brake fluid feed line
(
arrow
) from brake fluid reservoir.
Remove brake fluid intake and
Brakes