CHAPTER 6: SCPS COMMANDS
59
Examples
The following command specifies that the SCPS user database will be used to
authenticate users.
> server security authentication=local
The following command specifies that user authentication will be attempted on the
RADIUS server(s) defined in a Server RADIUS command, then, if that fails, the
SCPS local user database will be used.
> ser sec auth=rad,loc
Server Set command
The Server Set command changes SCPS address information.
When you enter this command, you are asked to confirm or cancel an SCPS reboot
to effect the changes.
Access: SCON
Syntax
SERVER SET IP=<
ip_address
>
MASK=<
subnet
>
[GATEWAY=<
gtwy
>]
Server Set Command Parameters
Parameter Description
IP=<
ip_address
>
SCPS IP address.
MASK=<
subnet
>
Subnet mask for the subnet on which the SCPS resides.
GATEWAY=<
gtwy
>
IP address of default gateway for routing IP packets.
Server SNMP command
The Server SNMP command enables or disables SNMP UDP port 161
SNMP processing.
For more information, see
Managing SNMP Structures
in Chapter 4.
Access: SCON
Syntax
SERVER SNMP ENABLE|DISABLE