3.4 Reinitializing the SCPS
Reinitializing the SCPS removes configured information. This may be useful when
reinstalling the SCPS at another location in your network.
The SCPS stores configuration information in FLASH databases. During reinitialization,
the FLASH erase has two phases. The first phase erases the SCPS configuration
database, which contains all nonvolatile data except the IP address. The second phase
erases the IP address and restores the SCPS to its factory default settings.
To reinitialize the SCPS:
1.
Locate the recessed INIT button on the front of the SCPS. You will need a non-
conductive, non-metallic tool that fi ts inside the recess.
2.
Insert the tool in the recess, then depress and hold the button. The ONLINE
LED will blink, indicating an SCPS initialization has been requested. You have
approximately seven seconds to release the button before any action is taken.
After seven seconds, the ONLINE LED will blink more rapidly to confi rm that
the SCPS confi guration database has been erased. Continuing to hold the INIT
button for a few more seconds will erase the IP address as well. The ONLINE
LED will blink faster to confi rm the deletion.
If any portion of FLASH is erased, the SCPS reboots when the INIT button is released.