Port Set command
The Port Set command changes SCPS serial port settings in the SCPS configuration
database. At least one keyword parameter and value must be specified. Some
changes require an SCPS reboot before they become effective. Others become
effective upon the next connection to the port.
Access: PCON or SCON
Syntax
PORT [<
port
>|ALL] SET
[BAUD=<
baud_rate
>]
[SIZE=<
size
>]
[PARITY=<
parity
>]
[STOP=<
stop_bits
>]
[FLOW=<
flow_ctrl
>]
[TIMEOUT=<
time-out>
]
[SOCKET=<
socket
>]
[CHAR=^<
cli_char
>]
[TOGGLE=NONE|DTR]
Port Set Command Parameters
Parameter Description
<port>
Port number in range 1-8 for an SCPS-8 or 1-16 for
an SCPS-16.
Default = port to which you are attached
ALL
Indicates that the port settings that follow should be
applied to all ports.
BAUD=<
baud_rate
>
Baud rate. Valid values are:
0|75|110|134|150|200|300|600|1200|2400|4800|7200|9600|
14400|19200|28800|38400|57600|115200
Default: = 9600
SIZE=<
size
>
Number of data bits per character. Valid values are 7 and 8.
Default = 8
PARITY=<
parity
>
Parity. Valid values are:
None
Specifi es no parity
Even
Specifi es even parity
Odd
Specifi es odd parity
Mark
Specifi es mark parity
Space
Specifi es space parity
Default = None