SERVSELECT™ IP SCPS INSTALLER/USER GUIDE
10
To avoid potentially fatal shock hazard and possible damage to equipment, please
observe the following precautions:
•
Do not use a 2-wire extension cord.
•
Test AC outlets at the computer and monitor (if used) for proper polarity
and grounding.
•
Use only with grounded outlets at both the computer and monitor. When using
a backup power supply (UPS), power the computer, the monitor and the SCPS
unit off the supply.
NOTE
:
The AC inlet is the main disconnect.
Rackmount safety considerations
•
Elevated Ambient Temperature: If installed in a closed rack assembly, the
operation temperature of the rack environment may be greater than room ambi-
ent. Use care not to exceed the rated maximum ambient temperature of the unit.
•
Reduced Airfl ow: Installation of the equipment in a rack should be such that the
amount of airfl ow required for safe operation of the equipment is not compromised.
•
Mechanical Loading: Mounting of the equipment in the rack should be such
that a hazardous condition is not achieved due to uneven
mechanical loading.
•
Circuit Overloading: Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of circuits might
have on overcurrent protection and supply wiring. Consider equipment name-
plate ratings for maximum current.
•
Reliable Earthing: Reliable earthing of rack mounted equipment should be
maintained. Pay particular attention to supply connections other than direct
connections to the branch circuit (for example, use of power strips).