Maintenance
5-50
Maintenance
Whizard
®
AirMax MACH 3 Operating Instructions and
Parts List
Manual No. 188000
September 1, 2009
Inspection and Maintenance of Power Unit
(
Continued
)
Adapter Plate
Inspect the adapter plate for cracks or chips. Replace the adapter plate if damaged.
Inspect o-ring for nicks, cuts or tears. Replace the o-ring if damaged.
Muffler
Inspect the muffler for broken or protruding wires. Replace the muffler if damaged.
Muffler may be cleaned with parts cleaner to remove build-up. Replace muffler if
excessive build up prevents proper cleaning.
Retainer
Inspect the retainer for cracks or chips. Replace the retainer if damaged.
Inspect the retainer threads for damage. Replace the retainer if damaged.
Adapter
Plate
O-Ring
Note:
Do not clean the muffler
while it is installed in the