4.3.4
Debug Mode
You can use the Mobile Manager Utility to help you monitor the IP address of the cellular devices after
you installed it in the remote field site.
Server:
You can Enable or Disable this function. The default value is disabled.
Server Address:
Type the Mobile Manager Utility's IP address in this field.
Server Port:
Type the Mobile Manager Utility's Port in this field. The device updates information to the
server through this port. The default is TCP port 2310.
Control Port:
The Control Port (TCP port) allows you to connect to this device. Default value 0 means
auto select.
Click the Apply button to apply the configuration changes.