BC-502/CRC
110
Rear Ctrl
Select and OK to enter the Rear Control Panel Switch diagnostic page.
Again the input voltage and sensor
output voltage are displayed in upper
area of back. If you turn a switch on or off
the switch on the display should mimic
the same movement.
Burner
Select and OK to enter the Burner diagnostic page. The square on the left
displays the Safety Lockout Condition. If all the lights are green the
computer will allow the burner to fire.
Safety lockouts prevent the burner from running if the following
conditions are true:
1.
+ FPM (movement).
2.
Actual Temp is higher than Set Temp.
3.
30 minutes of zero GPM (no
circulation).
4.
Master Switch is On.
5.
Temp Sensor failure (after 30
minutes).
If Safety Lockout shuts down the burner
while burning it will run in cool-down
mode for 45 seconds. Turning the burner
switch OFF will stop this process. The indicator lights on the right
represent the burner switches and relays.
Summary of Contents for BC-502/CRC
Page 1: ...INSTRUCTION MANUAL Model BC 502 CRC Asphalt Distributor ...
Page 42: ...BC 502 CRC 42 ...
Page 43: ...43 ...
Page 69: ...69 ...
Page 87: ...87 Stage 1 ...
Page 151: ...151 Figure 13 INNER WING ASSEMBLY Figure 14 HYDRAULIC SYSTEM ...
Page 152: ...152 Figure 15 REAR PANEL ASSEMBLY ...
Page 154: ...154 Figure 17 PUMBING AND VALVE ASSEMBLY ...
Page 156: ...156 Figure 19 PUMP DRIVE ASSEMBLY ...
Page 157: ...157 Figure 20 PRODUCT PUMP ...
Page 158: ...158 Figure 21 SIDE CONTROL BOX SCHEMATIC ...
Page 159: ...159 Figure 22 CAB CONSOLE SCHEMATIC ...
Page 160: ...160 Figure 23 VALVE BOX SCHEMATIC ...
Page 161: ...161 Figure 24 REAR CONTROL BOX SCHEMATIC ...
Page 162: ...162 Figure 25 REAR CONTROL BOX PROPANE SCHEMATIC ...
Page 163: ...163 Figure 26 HYDRAULIC LAYOUT ...
Page 164: ...164 Figure 27 HYDRAULIC SCHEMATIC ...