11 - 11
Icon
Parameter
Function/Action
Range Of
Value
Default
Value
36
Network Type
Not Used
-------
-----
37
Marker Type
Laser Marker operation
1: Turns ON when the machine is not sewing.
2: Turns On only in “Drive mode” and not sewing.
3: Same as above item 1 + it resets to ON
when the machine is powered ON.
4: Same as above item 2 + it resets to ON
when the machine is powered ON.
This feature is for DT/VT, and all X-Series.
1-4
1
38
Borer 2
Switches off the thread break detector for a
needle fitted with a boring device. Enter the
number of the needle that has the borer. Set to 0
if a boring device is not in use.
0 – 15
[Needles]
0
39
Borer 3
Switches off the thread break detector for a
needle fitted with a boring device. Enter the
number of the needle that has the borer. Set to 0
if a boring device is not in use.
0 – 15
[Needles]
0
40
Sequin size
L2
Sets the Sequin Size Change on Left side
0-99
0
41
Sequin size
R2
Sets the Sequin Size Change on Right side
0-199
0
42
Marker Type
Not Used
-------
-----
43
Rotary Sequin
Rotary sequin control
0: Only the last needle number is available for the
sequin device.
1: All needles are available for the sequin device.
2: 1~8 Needles are available (Prohibit only 9)
3: 1~7 needles are available (Prohibit 8~9)
4: 1~6 needles are available (Prohibit 7~9)
5: 1~5 needles are available (Prohibit 6~9)
6: 1~4 needles are available (Prohibit 5~9)
7: 1~3 needles are available (Prohibit 4~9)
8: 1~2 needles are available (Prohibit 3~9)
9: Only No.1 needle is available (Prohibit 2~9)
0-9
0