8
‐5
No. & Icon
Parameter
Function
Default
Value
Range of Values
7
Appliqué
Moves the pantograph forward for
easy placement of appliqué fabric.
The default movement is 1-1/2 times
the height of the pattern. A new
value can be programmed in the A.
Offset parameter.
0
0: Off
1: On
8
A H Offset
Sets the amount of distance in the H
and V direction that the pantograph
will move when Appliqué is on. If set
at 0, the pantograph moves forward
1-1/2 times the height of the pattern.
0
-3000
mm
~
3000
mm
9
A V Offset
10
Frame
Automatically moves the pantograph
forward at the end of the pattern, by
the height of the pattern, unless a
new value is programmed in F.
Offset parameter.
0
0: Off
1: On
11
F H Offset
Sets the amount of distance in the H
and V direction that the pantograph
moves when Frame is on. If set at 0,
the pantograph moves forward by the
height of the pattern.
0
-3000
mm
~
3000
mm
12
F V Offset