8
‐12
5. Sub-Soft Limits
Sub-Soft Limits is the function where you can program up to three different size frames using
#14 “Frame type” in the Program settings.
Two points, P1 and P2, are set to limit the possible embroidering area.
* The Sub-Soft limits P1 and P2 are set by moving the frame.
* This set range has to be within the limits of the MC software limits (#22 “Right limit”,
#23 “Left limit”, #24 “Back limit”, and #25 “Front limit”)
* This function is the same as “Chapter 7. 6 Setting Sub-Soft limits”, but the operation is a
little different.
1)
Press the Design Edit Key
.
2)
Select a design and press the B-key
icon to open the Program list.
3)
Use the Jog keys to select #14 “Frame type” setting.
4)
Change the #14 “Frame type” setting to 1, 2, or 3.
The “0” setting is the size of the frame as set by the MC software limits and cannot be
used to set the Sub-Soft limits. Selecting “0” will show and confirm the maximum
limits, but you cannot change them in this menu.
5)
Press the E- key
to display the Sub-Soft limit menu.
A Displays the currently selected frame type (example type 1 shown).
Use the E-key
if necessary, to exit to the Program list.
A
Summary of Contents for BEXT 120V
Page 1: ...B E X T Instruction Manual...
Page 13: ...Warning Labels Contents Hook Warning Label Belt Warning Label...
Page 20: ...1 Appearance and Components...
Page 21: ......