11 - 10
Icon
Parameter
Function/Action
Range Of
Value
Default
Value
30
Clamp Frame
Pneumatic Clamp Frame option.
0: OFF
1: Pneumatic Clamp Frame installed
51: Use with Madeira AFS
(Automatic Frame System)
0 – 99
0
31
Warm Up
Speed
Sets the machine speed for the warm-up function
200
rpm
–
MAX Speed
800
rpm
32
Warm Up End
Sets a load factor for main motor warm-up
function.
※
When set to 100, the warm-up function is
disabled.
50-100
%
100
%
33
Frame Option
Sets the gain parameter automatically
0: Portal Frame
1: Spider Frame
2: One Touch Frame
Note:
*This function is only activate with m/c equipped
with AC Servo Motors for V/H axis.
* Use this parameter if m/c encounters distortion
problems while running one of the listed inner
frames above due to pantograph load.
*Set to 1 and press the DRIVE button,
automatically rewrites the AC servo motor
parameter from G2 to G3.
*Set to 2, and press the DRIVE button,
automatically rewrites the AC servo motor
parameter from G2 to G4.
0 - 2
0
34
Sequin size
L1
Sets the Sequin Size Change on Left side
0-199
0
35
Sequin size
R1
Sets the Sequin Size Change on Right side
0-99
0