11 - 9
Icon
Parameter
Function/Action
Range Of
Value
Default
Value
23
Left Limit
Sets left soft limit – allowable distance the
pantograph can move to the left of the
mechanical origin.
0 – 3200
[mm]
500
24
Back Limit
Sets back soft limit – allowable distance the
pantograph can move to the front of the
mechanical origin
0 – 3200
[mm]
500
25
Front Limit
Sets front soft limit – allowable distance the
pantograph can move to the back of the
mechanical origin
0 – 3200
[mm]
500
26
LCD Mode
Not Used
-------
-----
27
LCD Bright
Sets the brightness of the LCD screen.
1: dark
2: bright
3: bright
4: bright
4
28
Roll to Roll
Activates the Roll-to-Roll function.
0 = Roll to Roll not used
1 = Manual Roll to Roll ON/ Roll to Roll m/c
* 1: Activated on stitch with a SE function code, the
needle will remain down in the fabric (D32 Icon
will also be displayed). Panto clips should be
released and then press the start bar to move the
pantograph back to the start origin. Or move the
panto to the position as set by values for F.offset
in (Program).
* For roll to roll m/c, set to 1 and set Roll to Roll
type (MSU2) to 1 (for normal roll fabric) or 2 (for
thinner roll fabric).
0 - 1
0
29
WS System
Sets WS System Active.
0 : OFF
1 : ON
0 - 1
0