171
8.1 T
YPES
OF
STATUS
MESSAGES
ALS
20X
256
5020
I2C Timeout 16
Timeout error while communicating via
the I
2
C Bus with device No. 16 (EEP-
ROM, contains manufacturing data).
Switch the machine off, wait 30 se-
conds and switch it back on.
Replace EEPROM
If the error message appears
repeatedly:
Contact the manufacturer.
5021
I2C Conf. 16
Confirmation error while communicating
via the I2C Bus with device No. 16
(EEPROM, contains manufacturing da-
ta).
5022
I2C Busy 16
Error while communicating via the I2C
Bus with device No. 16 (EEPROM, con-
tains manufacturing data). Device con-
stantly transmitting “busy” message.
5024
I2C BER 16
Error while communicating via the I
2
C
Bus with device No. 16 (EEPROM, con-
tains manufacturing data).
5026
MotorProtect CPU – (ALS 256) Dust filter liner exhausted.
This leads to overheating the ma-
chine.
– Cable between CPU board and Mo-
tordriver board not properly connect-
ed or defective.
– (ALS 20X) Voltage selection switch
set faulty.
– Motordriver board overheated or
defective.
Renew the dust filter liner. Let the
machine cool down
Check connection.
Check cable.
Check setting of the voltage selection
switch.
Switch the machine off, wait 30 se-
conds and switch it back on.
If the error message appears
repeatedly:
Replace motordriver board.
5065
OD Material end
– Occurs during operation with activat-
ed OD control.
– The material roll has reached the
critical roll diameter. The dispenser
will soon run out of label stock.
Be prepared to insert a new label roll.
5132
Bootloader PSU
Missing application in the power supply.
The power supply is in bootloader mode
during machine startup.
Load application into power supply.
Status Status text
Cause
Action to take