123
7.3 C
IRCUIT
BOARDS
ALS
20X
256
A
JP 901: Jumper controls pin 2 of the alternative label
sensor
– Preset: Jumper open
– Siehe “Changing light/dark switching at the product
sensor or the alternativ label sensor” auf Seite 51.
B
CN 906: Connection for alternative label sensor
C
JP 902: Jumper controls pin 2 of the product/start
sensor
– Preset: Jumper open
– Siehe “Changing light/dark switching at the product
sensor or the alternativ label sensor” auf Seite 51.
D
CN 905: Connection for product/start sensor
E
CN 904: Connection for (Wenglor) photoelectric la-
bel sensor
F
CN 903: Sensor connection for external roll diame-
ter control
G
CN 902: Connection for rotary encoder, for auto-
matic speed adjustment
H
CN 502: Supply voltage connection for applicator
interface (+24 V)
I
CN 501: Power supply unit connection
– Power supply for the board with 5 V and 24 V
J
CN 702: Connection to applicator interface
K
JP 601: Jumper micromonitor (Diagnostic software
for factory-internal use)
– Preset: open
L
JP 602: Jumper with no function
M
CN 802: Connection for additional motor driver
(optional)
N
CN 808: Sensor connection for internal roll diameter
control
O
CN 809: Connection for pressure roller switch
(optional)
P
CN 703: Connection for power supply (I
2
C bus)
Q
CN 801: Motor driver connection
R
CN 807: Connection for dancer arm sensor 1
(optional)
S
CN 806: Connection for dancer arm sensor 2
(optional)
T
CN 805: Connection for dancer arm sensor 3
(rewind unit)
U
CN 704: Connection for RFID read-write control
(optional)
V
CN 101: Debug interface
W
CN 401: Ethernet connection 10/100 Base T
X
D 401: Operation display for the Ethernet connec-
tion:
Y
CN 701: RS 232 connection
Z
CN 601: RS 485 operator panel connection
AA
CN 701: External operator panel connection
AB
CN 601: Slot for compact flash card
AC
CN 102: USB interface (device)
AD
CN 103: USB interface for optional internal use
AE
D 506: Green display to indicate 5 V supply
AF
CN 901: PLC signal interface
– For activating simple applicators
AG
D 507: Yellow display to indicate 24 V supply
AH
CN 907: Connection for the M12 socket for signal
inputs
AI
CN 908: Connection for the M12 socket for signal
outputs
LED
Meaning
Green
–
Continuously lit
: High transfer rate
(100 Mbit/s)
Yellow
–
Continuously lit
: Labeller is con-
nected with the network
–
Flashing
: Communicating with net-
work
Summary of Contents for ALS 204
Page 1: ...ALS 204 206 256 SERVICE INSTALLATION MANUAL Labeller Edition 8 3 2012 Original version ...
Page 2: ......
Page 223: ......