104
6.4 I
NTERFACE
COMMANDS
ALS
20X
256
6.4.1
Reference table
[104] Overview of interface commands
Command
Function
Can take values
#!An
– Activate interface [107A]
– Once the command #!A1 has been
given, all commands received are
interpreted as interface com-
mands.
n = Machine ID (is set using
INTER-
FACE PARA >EASYPLUGINTERPR > Dis-
penser ID no.
#!CLRE
Acknowledge status message (only
possible, if the quit method is not „N“)
#!CLRW
Reset warning status.
#!D
Dispense a label
#!ERRF
Get status message
#!Pn
– Deactivate interface
– Once the command #!P1 has been
given, the commands received are
no
longer
interpreted as interface
commands.
n = Machine ID (is set using
INTER-
FACE PARA >EASYPLUGINTERPR > Dis-
penser ID no.
#!PG<Function ID>#G
#!PGn
Gives readout of menu function set-
tings via the interface that is set up for
use [107].
<Function ID> = identification number
of menu function
n = [-1 , -2, -4, -8, -16, -32, -xx]
#PB s/n/<Function ID>=
<Value>[, <Function ID>=
<Value>]#G
Value assignment to one ore more
functions in a product profile.
s = number of the product profile
n = name of the product profile
<Function ID> = identification number
of menu function
#PC<Function ID>/ <Value>#G
#!PC<Function ID>/ <Value>
Adjusting a function in the function
menu
<Function ID> = identification number
of menu function
<Value> = Setting value of the func-
tion
#!SP
Stop dispenser
#!SR
Restart dispenser
#!WARF
Get warning status
#!XMn#G
Save diagnose dump in Flash and/or
send it to interface
n = [-99, -100]