108
6.4 I
NTERFACE
COMMANDS
ALS
20X
256
The #PC command
Syntax:
#PC<Function ID>/<Value>#G
– <Function ID>: Identification number of the function
– / : Separator
– <Value>: Value of the function (permitted values de-
pend on function type)
– #G declares end of command
Many of the functions need a system reset, be-
fore the changed setting takes effect. This can
be triggered at the operation panel of the de-
vice or by an Easy-Plug command
(#PC999999/-1#G).
Example:
#!A
#PC6000/10.0#G
– Sets the dispensing speed to 10.0 m/min:
– #!A sets interface to be ready to receive interface
commands
– 6000 = Function ID of the function
LABEL SETUP > Dis-
pense speed
– 10.0 = Speed in m/min
The
MACHINE SETUP > Store Parameters
function
saves all parameters, along with their function
IDs and current values, to the CF card as a text
file.
999999 = Function ID for Special functions; must be
used together with one of the values listed below:
Example:
#!A
#PC999999/-1#G
– Resets the machine
[109] Values for #PC.
Value Function
-1
Reset machine
1
When the
MACHINE SETUP > Factory settings
function is called, the current function settings
are used. Equivalent to the function setting
MACHINE SETUP > Default values
= “User
defined”
2
When the
MACHINE SETUP > Factory settings
function is called, the settings specified at the
factory are used. Equivalent to the function
setting
MACHINE SETUP > Default values
=
“Standard”