67
4.1 F
UNCTION
MENU
4.1 F
UNCTION
MENU
ALS
20X
256
“10M full duplex”:
Transfer rate = 10 MBit/s with
full
duplex
operation.
“100M Half duplex”:
Transfer rate = 100 MBit/s with
half duplex
operation.
“100M full duplex”:
Transfer rate = 100 MBit/s with
full duplex
operation.
MAC Address
function:
– Displays the MAC address of the CPU Board.
– This address cannot be altered via the menu.
SNMP Agent
function:
– Function is not yet supported.
SNMP password
function:
– Function is not yet supported.
FTP server
function:
– The file transfer protocol (FTP) server (RFC959) en-
ables access to the labeller's internal RAM disk and
to the compact flash card if one is in place. The FTP
server is multisession compatible, in that the user
name given when logging in is not verified. The
password must match the FTP password set (see
below).
– Settings [Enabled,
Disabled
]
Enabled: The FTP server is switched on.
Disabled: The FTP server is switched off.
– See “FTP server” on page 100.
FTP Password
function:
– To input the password for the FTP server.
default: avery
WEB server
function:
– The web server makes it possible
to set or read the values of functions from the menu
via a web browser
to control the operator panel of the labeller via a web
browser.
– See “Web server” on page 95.
WEB display refr
function:
– Defines the time, after which the web server display
is refreshed.
– Adjustment range: [0…20] s; default: 5 s
WEB admin passw.
function:
– Changes the admin password for the web server
– default: “admin”
– Access rights to functions are equivalent to those in
supervisor mode (see
MACHINE SETUP > Access author-
iz.
)
WEB supervisor p.
function:
– For changing the supervisor password for the web
server
– default: “supervisor”
– Access rights to functions are equivalent to those in
production mode (see
MACHINE SETUP > Access author-
iz.
)
Time client
function:
– Settings: [Disabled, Enabled]
Time server IP
function:
– IP address of the time server.
Enter the IP address in the form xxx.xxx.xxx.xxx
– Appears only if
INTERFACE PARA >NETWORK PARAM. >
Time client
= „Enabled“.
– Possible range for each xxx value: [0…255]
Sync. interval
function:
– Specifies the interval, after which the time is up-
dated from the time server.
– Setting range: [0…9999] s; default: 3600 s.
– Appears only if
INTERFACE PARA >NETWORK PARAM. >
Time client
= „Enabled“.
DHCP host name
function:
– Host name of the labeller.
– default: “Device Name” + the last 3 characters of the
MAC address
– Permitted characters: A-Z, a-z, 0-9, -
4.1.6
SIGNAL INTERFACE
Interface mode
function:
– Sets the operation mode of the standard signal in-
terface.
– Settings: [„
PLC signals
“, „Applic. signals“]
„PLC signals“: The signal interface provides PLC
signals.
„Applic. signals“: The signal interface provides
signals for applicator control.
Summary of Contents for ALS 204
Page 1: ...ALS 204 206 256 SERVICE INSTALLATION MANUAL Labeller Edition 8 3 2012 Original version ...
Page 2: ......