174
8.1 T
YPES
OF
STATUS
MESSAGES
ALS
20X
256
5204
Appl. Starterror
– Refers to the start input at the option-
al applicator interface.
– The device received another start
signal while applying a label.
– Prerequisite:
MACHINE SETUP > Start er-
ror stop
is set to “On”
.
Check the operation of the labeller;
increase distance between products
if required.
Set “Start error stop” function to “off”.
5205
Applicator gen.
General software error
Switch the machine off, wait 30 se-
conds and switch it back on.
– See “General software errors” on
page 168.
5206
Applicator resp.
A time limit was exceeded while commu-
nicating with the applicator interface
(AI).
Switch the machine off, then back on
again after half a minute.
If the error continues to occur after
switching on and off several times,
please contact our technical support.
5207
5208
5209
5210
Appl. driver x
(x=[1…4])
Short circuit or over-temperature at pow-
er output x of the applicator interface
(AI).
Check connections.
5212
Vx.x for AI rec
Wrong firmware for applicator interface
(AI) installed.
Install AI firmware version x.x.
5250
PLC Out overload
At least one PLC output signal is over-
loaded. Possible causes:
– Load to big
– Wrong wiring
– CPU board defective
Reduce load.
Correct wiring.
Replace CPU board.
5251
PLC 24V missing
24 V supply for PLC is missing. Possible
causes:
– 24 V cabling between power supply
and CPU is not available or defective
– Power supply is defective
– CPU is defective
Check voltage cable; replace if ne-
cessary.
Replace power supply.
Replace CPU board.
5252
PLC out disabled
PLC outputs are disabled. Possible cau-
ses:
– Watchdog timer expired
– Firmware error
– CPU board defective
Switch the machine off, wait 30 se-
conds and switch it back on.
– See “General software errors” on
page 168.
Replace CPU board.
5253
24V switched off
24 V output of the power supply is swit-
ched off. Possible causes:
– General firmware error
– CPU board defective
Switch the machine off, wait 30 se-
conds and switch it back on.
– See “General software errors” on
page 168.
Replace CPU board.
Status Status text
Cause
Action to take
[196] List of error messages