195
9.4 U
NWIND
UNIT
ALS
20X
256
Disconnect plug connection [228A] for unwind unit
sensor.
Remove dancer arm [229].
Remove bushing [228B] from casing.
Clean bushing and hole in casing.
Replacing unwind unit sensor
– Prerequisite: Dancer arm is removed [229].
Removal:
Remove control lever fixing screw [229D].
Remove nut [230B], remove cable bushing.
Remove 2 screws [230C] on lever plate [230A].
Remove shaft complete with brake.
Disconnect plug connection [231C] on unwind unit
sensor.
Remove 2 nuts [231B]; remove the unwind unit sen-
sor together with its PCB [231A].
[231] Disconnecting plug connection and removing unwind unit
sensor
[228] Disconnecting plug connection; removing bushing
[229] Dancer arm (removed from machine):
A
Brake
B
Shaft
C
Unwind unit sensor
D
Control lever fixing
[230] Loosening lever plate on rear side of dancer arm
A
B
C
A
B
D
A
C
B
C
B
A