106
6.4 I
NTERFACE
COMMANDS
ALS
20X
256
The #!PGn command
[106] Effects of different values used in the #!PG command
– The current set value for the function is returned as
ASCII text and ends with a line feed <LF> (0x0a). It
is possible to output the values of all the functions
together. These
can then be transferred to an-
other device (see #PC command).
– If an ID is not available, only <LF> is returned.
n =
Effect
-1
Values for machine-specific settings (e.g. sensor adjustment values) are
commented out
[107F]
(by
adding a “*” to the front of each). When settings are then transmitted to another labeller, the machine-
specific settings are
not
included in the information sent
.
-2
Values for machine-specific settings (e.g. sensor adjustment values) are
not
commented out [107F].
Machine-specific settings are consequently transferred along with the rest of the settings when these
are sent to another labeller.
-4
Additional output of comments. These comprise the name and value of the function in text form. Besides
this, a number of machine data [107B] are output at the start.
-8
Additional output of comments that comprise the type of function [108] and its range of permitted values
[107E].
For information on the function types see below.
-16
Additional output of the service data as a comment.
-32
Outputs the content of the product profiles.
-xx
Combination of two or more values of the range [-1, -2, -4, -8, -16, -32] by addition.
Example: (-16)+(-8)+ (-4)+(-2)=(-30).