165
7.7 A
PPLICATOR
I
NTERFACE
(
OPTION
)
ALS
20X
256
24 V supply voltage outputs: I
max
=10 mA
OD sensor in
– Input
– I
in
< 6 mA
– Connection for optional roll outer
diameter (OD) sensor
– CAUTION! - Initially, this signal in-
put is
deactivated
. The „OD sen-
sor in“ standard signal input (M12
connector) is activated. This set-
ting can be changed with
SIGNAL
INTERFACE >ACTIVE INPUTS > OD
sensor signal
OD sensor
– Power output
– I
out
< 500 mA
– Active, if the input „OD sensor“ is
set high
Offline
– Power output
– I
out
< 500 mA
– Active in configuration mode
– Not active in dispensing mode
– Inverted Ready signal
Signal name
Function